TANK TOP RETURN FILTER
Ports: 3/8”÷ 2” 1/2
Flow rates: 5 ÷ 700 l/min
Max. working pressure: 300 kPa (3 bar)
Max. test pressure: 500 kPa (5 bar)
Bursting pressure: 1 MPa (10 bar)
Fatigue test: 0 ÷ 300 kPa (3 bar) / 300.000 cycles
Bypass valve: Δp 170 kPa (1,7 bar) ± 0,2
Filter element collapse pressure:
Δp 300 kPa (3 bar)
(type CD-CV) - ISO 29
41
Δp 1 MPa (10 bar)
(type DR-VR-MV-MS-MN- FT-FC-FD-FV) - ISO 29
41
Working temperature: -25 ÷ +110°C
MATERIALS
Cover and head: aluminium
Bowl: polyamide (steel for size 004 and 055 to 160)
Seals: standard NBR; on request FKM
COMPATIBILITY (ISO 29
43:19
9
9
)
Full with fluids: HH-HL-HM-HV-HTG (according to ISO 6743/4).
For fluids different than the above mentioned, please contact our Sales Department.
All tests performed according to the following standards:
ISO 29
41: Element collapse resistance test
ISO 29
42: Production integrity test
ISO 29
43: Fluids compatibility
ISO 3723: End load test method
ISO 3724: Flow fatigue resistance method
ISO 3968: Pressure drop versus flow rate
ISO 168
8
9
: Multipass test.
For further information contact our Technical Dept.